Factory-direct distribution transformers & substations · Anqing, Anhui, China
WhatsApp & email: david@hengyuanpower.com · +86 187 5568 0508
Home › Products › 11 kV

11kV distribution transformers for 11/0.4, 11/0.415 and 11/0.433 kV networks

Factory-direct S11 three-phase oil-immersed transformers from 50 to 2500 kVA. Select the secondary voltage, protection and enclosure required for your utility or EPC project.

What it is

What is an 11kV distribution transformer?

An 11kV distribution transformer steps a medium-voltage 11kV supply down to the low voltage used by homes, commercial buildings, industrial plants and local distribution networks. The transformer is the core equipment; it can be supplied on its own or integrated with medium-voltage switchgear and low-voltage distribution equipment inside a packaged substation.

The 11 kV class covers most urban and rural distribution networks in Africa, the Middle East and South Asia, which is why it is the first range we publish prices for. Single unit or container load, the unit is the same: sealed corrugated tank, cold-rolled silicon steel core, full copper windings.

The three secondary voltages exist because different countries standardise differently — 400 V in most of Africa, 415 V in the UK-influenced grids, 433 V in parts of the Middle East. We build all three on the same platform, so the price does not change with the secondary voltage.

11 kV distribution transformers lined up for delivery
11kV / 415V distribution

11kV/415V secondary substation: transformer or packaged unit?

An 11kV/415V secondary substation takes an 11kV primary supply and distributes power at 415V. The most suitable scope depends on what is already installed at the site.

Transformer only

Choose a standalone 11/0.415 kV distribution transformer when the HV switchgear, LV panel, protection and installation room are already designed or supplied by others.

Typical rating: 50–2500 kVA. Full copper winding and routine test records are standard.

Complete packaged substation

Choose a European type packaged substation when the HV switchgear, transformer, LV distribution and protection need to arrive prewired, coordinated and tested in one outdoor enclosure.

Typical rating: 400–1250 kVA, with different compartment and cable-entry arrangements available.

For accurate selection, confirm whether the 415V network is three-phase four-wire, the required transformer vector group, LV fault rating and whether the local utility requires a ring-main unit.

Specification

ParameterRange
Rated capacity50 – 2500 kVA
Primary voltage11 kV
Secondary voltage0.4 kV, 0.415 kV or 0.433 kV
SeriesS11, three-phase, oil-immersed
WindingFull copper
Vector groupDyn11 (others on request)
Frequency50 Hz (60 Hz on request)
CoolingONAN; ONAF on request
TankCorrugated sealed tank, anti-corrosion finish
TestsRoutine test on every unit, record supplied
Selection guide

How to choose kVA for an 11 kV feeder

Start with the calculated maximum demand, power factor and expected daily load profile. Then confirm the utility or project standard, because some networks fix the transformer size for a feeder regardless of the connected load.

Typical ratingCommon dutyWhat to confirm
50–100 kVASmall rural or commercial distribution pointSingle-phase load share, voltage-drop limit and pole/platform arrangement
160–250 kVAVillage network, residential block or small plantMaximum demand, future load and allowed loading above nameplate rating
315–630 kVAUrban distribution, workshops and medium commercial buildingsFault level, LV switchgear rating and available installation space
800–1250 kVAIndustrial plants, larger buildings and network reinforcementCooling method, parallel operation, cable entry and transport limits
1600–2500 kVAHeavy industrial or high-capacity distribution pointsSite conditions, loss evaluation, protection scheme and delivery route

The table is an application guide, not a substitute for the project load calculation. Add spare capacity deliberately and follow the utility’s approved transformer schedule and loss limits.

11 kV or 33 kV?

Choose 11 kV

For the local medium-voltage distribution step in networks standardised at 11 kV. It is commonly used close to residential, commercial and light-industrial loads where the utility already operates an 11 kV feeder.

Review published 11 kV transformer prices

Choose 33 kV

Where the local utility, industrial network or renewable project uses 33 kV for heavier or longer circuits. Voltage class is a system decision; do not select it only because a lower-current transformer appears smaller.

Compare 33 kV distribution transformers

For an outdoor installation without a transformer building, compare a European type packaged substation with an HV room, transformer room and LV room delivered as one coordinated unit.

Representative prices

Ex-works, USD per unit. The full list covers 16 ratings from 50 to 2500 kVA.

CapacityEx-works priceTypical use
50 kVAUSD 1,821Small rural feeder, pole or platform mounted
100 kVAUSD 2,658Village distribution, small commercial load
250 kVAUSD 4,584Residential block, light industry
500 kVAUSD 7,437Urban distribution substation
1000 kVAUSD 12,231Industrial plant, commercial building
2500 kVAUSD 25,502Large industrial or network reinforcement

See all 16 ratings and terms

Prices move with copper: every USD 1,600 per tonne changes them by roughly 5.5%. Confirmed at order date.

Ordering terms

MOQ

10 units per order. Mixed ratings are accepted — normal when you are filling a container.

Lead time

30–45 days after deposit, depending on the rating mix and quantity.

Branding

Our nameplate or yours. Nameplate, manual and carton printing under your brand.

Payment: T/T 30% deposit, 70% before shipment. L/C at sight for tender orders. Terms confirmed per order.

11 kV buying guide and FAQs

QuestionAnswer
What is an 11kV/415V secondary substation?It is an 11kV-to-415V distribution point. It can be a transformer supplied on its own, or a complete packaged substation including HV switchgear, transformer, LV panel and protection.
Can you supply 11/0.415 kV instead of 11/0.4?Yes, at the same price. We build 0.4, 0.415 and 0.433 kV secondary on the same platform.
Is 60 Hz available?Yes, on request. Tell us the destination country and we will confirm the design.
Copper or aluminium windings?Full copper as standard. Aluminium is available on request at a lower price.
Do you supply the type test report?Type test and energy efficiency reports are available for the series on request. Every unit also gets a routine test record.
What is the lead time for a container?30–45 days after deposit. We issue the loading plan before the container is stuffed.
What should I include in the RFQ?Send the rating list, primary and secondary voltages, frequency, quantity, installation environment, destination port and any required standards or drawings.

Need a different voltage class? See 33 kV distribution transformers, a packaged secondary substation, or custom builds to your drawing.

Send a rating list

Tell us the capacities, quantities and destination port. We will confirm the copper price and issue a quotation the same day.

Chat on WhatsApp